APC Metered Rack PDU Zero U - power distribution unit - 22 kW - 22000 VA

Category: Power distribution units PDUs
  $1,752.00
 
Quantity:
Add to Cart Print
 

View all Power distribution units PDUs by APC by Schneider Electric >>


Product Id: 19944207

Description: APC Metered Rack PDU Zero U - Power distribution unit (rack-mountable) - AC 400 V - 22 kW - 22000 VA - 3-phase - Ethernet 10/100, RS-232 - input: IEC 60309 32A - output connectors: 18 - 0U - black

Mfr Part #: AP7856A

MSRP: $2,050.00

APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Key Points
  • Toolless Rack Mounting Capabilities
  • Local and web-based monitoring
  • Network management capability
  • Local Current Monitoring Display
  • Load indicator LED
  • Alarm Thresholds
  • Flash Upgradeable
Product Features
  • Toolless Rack Mounting Capabilities
    Server cases do not require additional tools to mount into NetShelter Enclosures, which allows the users to quickly and easily mount units in the rear of the enclosure
  • Local and web-based monitoring
    Status available to customers both in the data center and remotely
  • Network management capability
    Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet
  • Local Current Monitoring Display
    The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
  • Load indicator LED
    Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits. (Note: Only available with units with local current monitoring feature)
  • Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)
  • Flash Upgradeable
    Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)